No products in the cart.
TL-PNC6-UT24M Techlogiks 24 Ports 01U 19Inch Fully Loaded Patch Panel with Rear Cable Management
Techlogiks
Category 6 Unshielded Patch Panel
Techlogiks Cat 6 modular patch panel utilizes quad frame modules offered with 8-contact inserts wired to Insulation Displacement Connectors (IDC}. Fully automatic press-fit production of PCB assembly to ensure consistency quality and complies with international standards.
Applications
- 10008ASE-T, 100BASE-Tx, 10BASE-T, 155M ATM, 4/16MB Token
- 100Mbps TP-PMD, /SON, ADSL, Analog & Digital Voice {VoIP)/
- Power over Ethernet (PoE}, Control Signal.
Standards
- Lead-free & RoHS2
- ANSl/TIA-568-C.2, ANSl/TIA- 1096-A {FCC Part 68}, /SO/IEC 11801 2nd edition and CENELEC EN 50173-1.
- Level A reliability requirements of /EC 60603-7-2 and /EC 60603-7-4 for
- Compatible for T568A and T5688 wiring
$ 77.60TL-FDB-W24-SC-SX Techlogiks Wall Mount Fiber Distribution Box
Techlogiks TL-FDB-W24-SC-SX
Wall Mount Fiber Distribution Box
Applications:
- Telecommunication Networks
- Local Area Networks
- FTTH
- CATV Networks
- Active Device Termination
Features & Benefits:
- Low excess loss & high
- Retractable Splicing Tray
- Convenience and ease of handling
- Indoor Use, Outdoor use customable
Â
Distribution Shelf :-
Shelves are designed with enough capacity for fiber splices and it is suitable for 12 to 72 fiber splices. It is made from fabricated mildvsteel not less than 1.2mm thick or equivalent and painted in good condition. The Fiber Distribution Frame shall be of corrsion resistance and robust construction and shall allow both top or bottom entry for access to this splice trays
$ 176.9741523000ZY DATWYLER 48F LC Patch Pannel
DATWYLER 41523000ZY
SCOPE OF DELIVERY
Splice box with
– two straight cable entries
– one screwed cable gland M20
– coloured pigtails with measurement report
– FO adapters, fastened by screws
– splice trays with cover
– splice holder for 12 x crimp splice protectors
– Delivery without splicing protection$ 354.49NN01408.SM12 BELDEN LC 24 Port Patch Pannel Half Loaded
BELDEN NN01408.SM12Â
1U FiberExpress@EASE 12 Duplex LC (24 fiber) SM Termination/Splice
Patch Panel – Half loadedConstruction
Weight: 2.500 kg
Height: 44 mm
Width: 482 mm
Depth: 251.5 mm$ 200.11FT3LC900PS01 BELDEN LC SIMPLEX PIGTAIL OM3 LC 50 Micron 2M
BELDEN FT3LC900PS01 Cable Assemblies – FX FIELD-TERMINATION PIGTAIL
General Description:
FX FIELD-TERMINATION PIGTAIL, OM3, LC SIMPLEX, TIGHT BUFFER 900 UM, SINGLE-ENDED, 2M,
AQUA BUFFERMaterials
Materials:
Description Type Material Color
Connector end 1 LC Plastic Aqua
Boot end 1 Rubber Aqua
Ferrule end 1 2.5mm Zirconia-Ceramic White
Jacket 900 um Tight Buffer OFN Aqua$ 85.76A0644489 BELDEN Cable Manager 1U, Black
BELDEN A0644489 Connectivity Accessories – Cable Management Accessories
General Description:
Organizer Panel, 1U, Black
Usage (Overall)
Suitable Applications: Patch Panels in rack or cabinet installations
Related Parts: Multi-Rack, Patch Panel in rack or cabinet
Physical Characteristics (Connectivity)
Dimensions
Dimensions:
Height (mm) Width (mm) Depth (mm)
60.960 482.600 86.360
Materials
Materials:
Description Material Color
Panel Steel, # 16 Gauge Black Powder Paint$ 25.05352-SLCLC02SH Norden SM Fiber LC Adaptor
Norden 352-SLCLC02SH
APPLICATIONS
CATV
Active device/Transceiver, Telecommunication networks
Multimedia Data processing networks
Test equipment, Premise installations
Gigabit Ethernet
Adaptor Material High Impart flame retardant thermoplastic UL94-V0
Capillary Diameter Tolerance (Single Mode) 126 ± 0.5 μm
Capillary Diameter Tolerance( Multimode) 127 ± 0.5 μm
Operating Temperature -40 ºC to +85 ºC
Storage Temperature: -40 ºC to +85 ºC
Mating Durability > 500 Mating Cycles
ORDERING INFORMATION
Part Number Description
351-SLCLC LC Singlemode Simplex Adaptor
351-SLCLC02 LC/APC Singlemode Simplex Adaptor
351-MLCLC LC Multimode Simplex Adaptor
352-SLCLC LC Singlemode Duplex Adaptor
352-SLCLC02 LC/APC Singlemode Duplex Adaptor
352-MLCLC LC Multimode Duplex Adaptor
351-SLCLCSH LC Singlemode Simplex Shutter Adaptor
351-SLCLC02SH LC/APC Singlemode Simplex Shutter Adaptor
351-MLCLCSH LC Multimode Simplex Shutter Adaptor
352-SLCLCSH LC Singlemode Duplex Shutter Adaptor
352-SLCLC02SH LC/APC Singlemode Duplex Shutter Adaptor
352-MLCLCSH LC Multimode Duplex Shutter Adaptor$ 2.99351-SSCSC02 Norden SC/APC Singlemode Simplex Adaptor
Norden 351-SSCSC02
OPTICAL PERFORMANCE DATA
Item Single mode Multimode
PC UPC APC 62.5/125 50/125 50/125
10G
Insert. Loss/Adaptor (single Fibre) 0.2 dB Max. (0.15 dB typ.) 0.3 dB Max. (0.25 dB typ.)
Return Loss ≥ 45 dB ≥ 50 dB ≥ 60 dB N.A
Insert. Loss/MTRJ 0.5dB Max. (0.45 dB typ.) 0.5 dB max. (0.45 dB typ.)
Pull strength ≥ 98 N ≥ 98 N ≥ 98 N ≥ 98 N$ 1.91341-1OS2S315 Norden SC APC Pigtail OS2 PVC 1.5m
Norden 341-1OS2S315 SCAPC Pigtail OS2 PVC 1.5m
MECHANICAL DATA
COMPLIANCE
ISO/IEC 11801
EN50173 -1,ANSI TIA/EIA 568B
FIBRE PIGTAIL
Fibre pigtails are used in permanent connections between patch
panels and incoming cables / single blown fibres. Pigtails are preconstructed
with connectors. Connector options include small form
factors such as LC, E2000 and MT-RJ as well as SC, FC and ST. These are
based on 900μm tight buffered cores (600μm MT-RJ) and suitable for
internal use only inside suitable Fibre Management Systems
www.nordencommunication.com
Fibre System
Crush (N) 800
Impact (Nm) 0.2
Operating Temperature -10°C to +70°C
Installation temperature 0°C to +70°C
Temp – Installation 0°C to +70°C
Bend Radius 50mm (min)
Fibre Type Max. Attenuation
(dB/km)
850nm 1300nm 1310nm 1550nm
OM1 62.5/125μm ≤2.7 ≤0.6 – –
OM2 50/125μm ≤2.5 ≤0.7 – –
OM3 50/125μm ≤2.3 ≤0.6 – –
OM4 50/125μm ≤2.3 ≤0.6 – –
OS1 9/125μm – – ≤0.34 ≤0.20
OS2 9/125μm – – ≤0.34 ≤0.24
Min. Overfill Launch
Bandwidth
(Mhz•km)
Min. Gigabit Ethernet Link
Distance (m)
Gigabit 10Gigabit
850nm 1300nm 850nm 1300nm 850nm
≥200 ≥600 275 550 –
≥500 ≥500 550 550 –
≥1500 ≥500 1000 600 300
≥3500 ≥500 1000 600 550
– – – – –
– – – – –
OPTICAL PERFORMANCE DATA (CONNECTOR)
ORDERING INFORMATION
ORDERING GUIDE
www.nordencommunication.com
Fibre System
FIBRE PIGTAIL
Description Part Number
Singlemode OS2
SC/APC 1m PVC SC/APC OS2 PVC 1M PIGTAIL 341-1OS2S310
SC/APC 1.5m PVC SC/APC OS2 PVC 1.5M PIGTAIL 341-1OS2S315
SC/APC 2m PVC SC/APC OS2 PVC 2M PIGTAIL 341-1OS2S320
SC/APC 3m PVC SC/APC OS2 PVC 3M PIGTAIL 341-1OS2S330
SC/APC 1m LSZH SC/APC OS2 LSZH 1M PIGTAIL 342-1OS2S310
SC/APC 1.5m LSZH SC/APC OS2 LSZH 1.5M PIGTAIL 342-1OS2S315
SC/APC 2m LSZH SC/APC OS2 LSZH 2M PIGTAIL 342-1OS2S320
SC/APC 3m LSZH SC/APC OS2 LSZH 3M PIGTAIL 342-1OS2S330$ 6.81N205.624 Nexans Adapter DSC-DSC Single mode
Nexans N205.624
LANmark-OF Snap-in Adapter DSC-DSC Single mode
Description
LANmark-OF snap-in adapters have been designed for snapping into the
modular OF patch panels and ZD boxes. They are available in single SC,
dual SC, LC duplex and MT-RJ version. The 2 Small Form Factor connector
types offer double density, as two fiber connections are offered on the SCtype
footprint. Installation time is saved as the snap-in concept replaces
the time-consuming screwing attachment of coupling devices.
Materials
· Adapter Housing: PBT, 15% Glass
· Sleeve Holder: PBT, 20% Glass
· Dust Cap: PP
· Spring:SUS 304 CSP 3/4 H
· PB Sleeve: PB – inner diameter 2,48mm – length 11.4mm
· Zirconia Sleeve: ZA Ceramic – inner diam.: 2.48mm -length11.4mm
Technical Specifications
Insertion Loss: < 0.2 dB
Sleeve Preservation Strength: 2.0 ~ 5.9N (200gf ~600gf)
JIS Z9015 standard l: 1 time pull out
NAMl test AQL = 0.25%
Plug Connect/Disconnect Strength: Less than 19.6N (2Kgf)
Sealing Pull Strength: Less than 98.0N (10Kgf)
Plug Removal Strength: Less than 68.6N (7Kgf)$ 8.17N205.617 Nexans Duplex LC Snap-In Adaptor Multimode Aqua
11.4mm
Technical Specifications
Insertion Loss: < 0.2 dB
Sleeve Preservation Strength: 2.0 ~ 5.9N (200gf ~600gf)
JIS Z9015 standard l: 1 time pull out
NAMl test AQL = 0.25%
Plug Connect/Disconnect Strength: Less than 19.6N (2Kgf)
Sealing Pull Strength: Less than 98.0N (10Kgf)
Plug Removal Strength: Less than 68.6N (7Kgf)$ 6.26